Hiconics's medium voltage drive has new cabinet type and power-cell structure and smaller volume. The power unit and transformer are arranged in front and back, with compact structure. Through thermal analysis design, on-site installation costs and infrastructure costs can both be reduced on the basis of ensuring heat dissipation.

Contact us


Products

Technical Parameters of 10kV/315~800kW General Medium Voltage Drive

VoltageMotor Power(KW)Output Capacity(KVA)ModelWeight
(kg)
Dimension
(W*H*D)
Cabinet Type
10kV315400HIVERT-Y/T 10/02328902150×1400×2400
2150×1400×2400
2815×1400×2400
LL1.1
LL1.1P
LL1.1Q
355450HIVERT-Y/T 10/0263050
400500HIVERT-Y/T 10/0313260
450560HIVERT-Y/T 10/0333350
500630HIVERT-Y/T 10/0403459
560700HIVERT-Y/T 10/0423540
630800HIVERT-Y/T 10/0483652
710900HIVERT-Y/T 10/0523769
8001000HIVERT-Y/T 10/0613829
315400HIVERT-Y/T 10/02336504000×1400×2000
4000×1400×2000
4665×1400×2000
LB1.2
LB1.2P
LB1.2Q
355450HIVERT-Y/T 10/0263740
400500HIVERT-Y/T 10/0313850
450560HIVERT-Y/T 10/0334050
500630HIVERT-Y/T 10/0404150
560700HIVERT-Y/T 10/0424230
630800HIVERT-Y/T 10/0484300
710900HIVERT-Y/T 10/0524430
8001000HIVERT-Y/T 10/0614550
9001150HIVERT-Y/T 10/06539504300×1600×2250
4300×1600×2250
4965×1600×2250
4300×1600×2250
4300×1600×2250
4965×1600×2250
LL2.1
LL2.1P
LL2.1Q
LB2.1
LB2.1P
LB2.1Q
10001250HIVERT-Y/T 10/0774840
11201400HIVERT-Y/T 10/0865150
12501600HIVERT-Y/T 10/0965280
14001800HIVERT-Y/T 10/1045580
16002000HIVERT-Y/T 10/1155750
18002250HIVERT-Y/T 10/1306040
20002500HIVERT-Y/T 10/1546250
20002500HIVERT-Y/T 10/154P77904750×1600×2250
4750×1600×2250
5415×1600×2250
4750×1600×2250
4750×1600×2250
5415×1600×2250
LL3.1
LL3.1P
LL3.1Q
LB3.1
LB3.1P
LB3.1Q
22502800HIVERT-Y/T 10/1658290
25003200HIVERT-Y/T 10/1928760
28003500HIVERT-Y/T 10/2059265
32004000HIVERT-Y/T 10/2439765
36004500HIVERT-Y/T 10/26010265
40005000HIVERT-Y/T 10/304134207200×1400/1600×2400
7550×1400/1600×2400
LL4.1
LB4.1
45005650HIVERT-Y/T 10/32514120
50006300HIVERT-Y/T 10/36414620
55007000HIVERT-Y/T 10/40014720
63008000HIVERT-Y/T 10/45515670
63008000HIVERT-Y/T 10/462P204009300×1400/1600×2400
9950×1400/1600×2400
LL5.1
LB5.1
71009000HIVERT-Y/T 10/50021300
800010000HIVERT-Y/T 10/600224009400×1400/1600×2400/2600
10050×1600/1400×2400/2600
LL5.1.1
LB5.1.1
1000012500HIVERT-Y/T 10/8004640011600×1600×2400/2600
13000×1600×2400/2600
LL6.1
LB6.1
More Options

Back


Specification of 10kV/315-800kw General Medium Voltage Drive

ItemParameters
VFD rated power210~28000kVA※
Rated voltage3.3kV~11kV(-20%~+5%)※(Out of range, special instructions required)
Rated Frequency50Hz/60Hz(-10%~+10%)※
Control Power380VAC, 30kVA
Rated input power factor≥0.96
Effciency>96%
Output frequency range0~80Hz※
Speed accuracy±0.5%(Open loop vector) ±0.1%(close loop vector)
Instantaneous over-current protection150%( Can be customized according to user requirements)
Over capacity120% load for 120s
Torque limitation10%~150%
Analog input3 ways 4~20mA/Excitation feedback 4~20mA(Customized)
Analog output4ways 4~20mA
Host communicationIsolated RS485 interface, ModBus RTU, Profibus DP(optional), Industry Ethernet
Acceleration and deceleration time5s~6000s ( related to load)
DI14 inputs/22 outputs (Output 8 ways can be defined)
Environment temperature-5~+45℃※
Storage/transportation temperature-25~+55℃※
Cooling methordAir forced cooling (AF) / Water cooled (WF)/Air forced water cooled (AFWF)
Humidity<95%, no condensation
Altitude≤1000m, when altitude is higher than 1000m, each 100 meter increasing needs 1%
derating of VFD
DustNon-conductive, no causticity, <6.5mg/dm3※
Protection levelIP30※
Cabinet colorsRAL 7032(customized)




VFD Application Industries and Fields


HIVERT Standard medium voltage VFD series is widely used in various fields in national economy, exported to Europe, Middle East, Southeast Asia etc.. Perfect solutions for soft start, speed adjusting, energy saving and intelligent control of medium voltage AC motors (including synchronous and asynchronous motors) could be supplied to customers. Typical application industries are:


Cement
Application Of VFD In Cement

Kiln draft fan

Kiln gas blower

Separator fan

Kiln head fan

High temperature fan

Cement mill fan

Dust removal fan

Circulating fan

Grate cooler

Raw material mill fan

Raw material mill

Coal mill

Kiln tail fan

Rotating kilntransmission

Compressive force draftfan

Electricity
Application Of VFD In Electricity

Powder exhaust fan

Booster fan

Force draft fan

Induced draft fan

Condensation pump

Slurry pump

Water and energy storage pump Circulating water pump

Boiler (feed) pump

Compressor

Municipal
Application Of VFD In Municipal

Aeration fan

Induced draft fan

Force draft fan

Force pump

Medium water pump

Sewage pump

Hot water circulating pump

Lifting pump

Cleaning water pump

Water supply pump

Metallurgy
Application Of VFD In Metallurgy

Induced draft fan

Secondary de-dusting fan

Force draft fan, Feeding pump

Compressing blower

Blast furnace blower

Blast/ Converter de-dusting fan

Electric furnace de-dusting fan

Sulfur dioxide blower

Slag-flushing pump, Mud pump

De-scaling pump

Water-delivery pump

Phosphorus removal pump

Gas compression pump

Kneading machine

Oxygen compressor

Coal Mines & Minerals
Application Of VFD In Coal Mines & Minerals

BFDS

De-dusting fan

Main fan

Axial flow fan

De-scaling pump

Mud pump

Slurry pump

Clean water pump

Feeding pump

Stirring pump

Agitating pump

Drainage pump

Medium pump

Band conveyor

Kilndrive

Petrochemical
Application Of VFD In Petrochemical

Booster fan

Induced draft fan

Pipeline transportation

pump

Water injection pump

Feed water pump

Submerged pump

Oil transfer pump

Brine pump

Circulating water pump

Compressor

Others
Application Of VFD In Other Industries

Pump test stand

Inverter power supply test stand

Motor test stand

Wind tunnel test

High-quality Variable Frequency Drive

Stable, Intergrated Solution, Alliance

Looking For High-quality Variable Frequency Drive, SVG Generator & Energy Storage System Service?

Related Medium Voltage Drive

Latest News & Blog

MORE +
Understanding SVC: The Role of Static Var Compensators in Modern Power Systems
May 28-2024
Read More
The Role of Solar Battery Storage in Industrial Energy Management
May 18-2024
Read More
+
You are going to jump to the third platform. Do you confirm the jump? It will jump after your confirmation.